Your go-to online shop for laboratory and test products. Our website offers you the convenience of accessing our complete product range in one place. With just a click, you can explore a diverse selection of high-quality laboratory equipment, reagents, consumables, and diagnostic kits. We have carefully curated our inventory to cater to various scientific disciplines, ensuring that you find everything you need for your research, diagnostics, or quality control endeavors. Experience the ease of browsing and finding the right products for your laboratory needs on our user-friendly website.
Order-No. | Product name | Tests/Size | Intended use | Quote Request |
---|---|---|---|---|
G321
|
HardyCHROM™ ESBL, 15x100mm Plate, 18ml
|
10 plates/bag
|
HardyCHROM™ ESBL is a selective and differential chromogenic medium which is intended for
the qualitative and presumptive detection from stool specimens of: 1) Enterobacteriaceae that are
potentially non-susceptible to ceftazidime and cefpodoxime; and 2) Extended-spectrum
betalactamase (ESBL)-producing Escherichia coli, Klebsiella pneumoniae and Klebsiella oxytoca. |
|
G323
|
HardyCHROM™ CRE, 15x100mm Plate, 18ml
|
10 plates/bag
|
HardyCHROM™ CRE is a selective and differential chromogenic agar medium intended for the
qualitative and presumptive detection from stool specimens of Escherichia coli that are nonsusceptible to carbapenems as pink colonies and KES (Klebsiella aerogenes, Klebsiella oxytoca,
Klebsiella pneumoniae, Enterobacter cloacae complex, and Serratia marcescens) that are nonsusceptible to carbapenems as blue colonies. |
|
G327
|
HardyCHROM™ SS NoPro Agar, 15x100mm Plate, 21mL
|
10 plates/bag
|
Hardy Diagnostics HardyCHROM™ SS NoPro (no-Proteus) Agar* is recommended for the selective isolation and
differentiation of Salmonella and Shigella spp. from stool. HardyCHROM™ SS NoPro Agar is intended as a
primary screening tool to distinguish Salmonella and Shigella spp. from non-pathogenic enteric bacteria based on colony color, while inhibiting the growth and characteristic swarming of Proteus spp. The enhanced inhibition of Proteus reduces the expense involved in working up non-pathogens that could mimic enteric pathogens. Further species confirmation of suspect colonies via conventional or automated methods is recommended. |
|
G376
|
KF Streptococcus Agar, 15x100mm Plate, 19ml
|
10 plates/bag
|
Hardy Diagnostics KF Streptococcus Agar is intended for the selective isolation and enumeration of fecal
streptococci (including Enterococcus ) from water and food samples by direct culture or membrane filtration. (1,2) This product is not intended to be used for the diagnosis of human disease. |
|
H05
|
Brucella Agar with H & K, 15x150mm Plate, 69ml
|
10 plates/bag
|
Hardy Diagnostics Brucella Agar with H & K is recommended for use in the primary isolation and cultivation of anaerobic microorganisms. |
|
HVB10
|
Media Bag, Empty, Sterile, 100ml
|
10 plates/box
|
Hardy Diagnostics HardyVal™ à la carte products are recommended for routine use in the monitoring of aseptic procedures used in the preparation of Compounded Sterile Preparations (CSPs). HardyVal™ à la carte components can be purchased separately and used to create customized proficiency tests that most closely resemble the laboratory's procedures. In addition, Tryptic Soy Broth (TSB), also known as Soybean Casein Digest Broth, in HardyVal™ à la carte complies with the harmonized European, U.S. and Japanese Pharmacopoeias for determining the microbial quality of non-sterile products. |
|
HVB5
|
Tryptic Soy Broth (TSB), USP, 1L IV Bag, 700ml
|
5 bags
|
Hardy Diagnostics HardyValTM CSP Medium-Risk Level Media-Fill Challenge Test Kits are
recommended for routine use in the monitoring of proficiency testing and aseptic procedures used in
Compounding Sterile Preparations (CSPs). Each kit contains the necessary materials for one pharmacist
or technician to perform the annual medium-risk level media-fill challenge testing as specified in USP
Chapter <797>.
This product is not intended to be used for the diagnosis of human disease. |
|
HVH1
|
High-Risk Level Media-Fill Challenge Test Kit
|
Single-Use Kit
|
Hardy Diagnostics HardyValTM CSP High-Risk Level Media-Fill Challenge Test Kit is recommended for routine use in the monitoring of aseptic procedures used in Compounding Sterile Preparations (CSPs). The kit contains the necessary materials for one pharmacist or technician to perform the semi-annual high-risk level media-fill challenge testing as specified in USP Chapter <797>.
This product is not intended to be used for the diagnosis of human disease. |
|
HVL1
|
Low-Risk Level Media-Fill Challenge Test Kit
|
Single-Use Kit
|
Hardy Diagnostics HardyValTM CSP Low-Risk Level Media-Fill Challenge Test Kit is recommended for
routine use in the monitoring of aseptic procedures used in Compounding Sterile Preparations (CSPs).
The kit contains the necessary materials for one pharmacist or technician to perform the low-risk level
media-fill challenge testing as specified in USP Chapter <797>.
This product is not intended to be used for the diagnosis of human disease. |
|
HVM1
|
Medium-Risk Level Media-Fill Comprehensive Challenge Test Kit – Bag
|
Single-Use Kit
|
Hardy Diagnostics HardyValTM CSP Medium-Risk Level Media-Fill Challenge Test Kits are
recommended for routine use in the monitoring of proficiency testing and aseptic procedures used in
Compounding Sterile Preparations (CSPs). Each kit contains the necessary materials for one pharmacist
or technician to perform the annual medium-risk level media-fill challenge testing as specified in USP
Chapter <797>.
This product is not intended to be used for the diagnosis of human disease. |
|
HVM2
|
Medium-Risk Level Media-Fill Basic Challenge Test Kit – Vials
|
Single-Use Kit
|
Hardy Diagnostics HardyValTM CSP Medium-Risk Level Media-Fill Challenge Test Kits are
recommended for routine use in the monitoring of proficiency testing and aseptic procedures used in
Compounding Sterile Preparations (CSPs). Each kit contains the necessary materials for one pharmacist
or technician to perform the annual medium-risk level media-fill challenge testing as specified in USP
Chapter <797>.
This product is not intended to be used for the diagnosis of human disease. |
|
HVR1
|
HardyValTM CSP RANDOM TEST KIT
|
5 tests/kit
|
Hardy Diagnostics HardyValTM Random Test Kit is recommended for use in quality assurance monitoring
of Compounded Sterile Preparations (CSPs), as an indicator of gross microbial contamination of
therapeutic solutions.
This product is not intended to be used for the diagnosis of human disease. |
|
K02
|
Modified Diamonds Medium, 16x100mm Tube, 6ml
|
20 tubes/box
|
Hardy Diagnostics Modified Diamonds Medium is recommended as an enriched and selective medium for the
isolation and cultivation of Trichomonas species from clinical specimens, especially T. vaginalis. |
|
K54
|
SabDex Broth, 16x125mm Tube, 10ml
|
20 tubes/box
|
Hardy Diagnostics Sabouraud Dextrose Agar, Sabouraud Dextrose Broth, and Sabouraud Dextrose Agar, Emmons are recommended for the isolation, cultivation, and maintenance of non-pathogenic and pathogenic species of fungi andyeasts. Sabouraud Dextrose Agar with Chloramphenicol, Sabouraud Dextrose Agar with Chloramphenicol and Gentamicin, and Sabouraud Dextrose Agar with Chloramphenicol and Tetracycline are recommended for the selective isolation of fungi and yeasts from clinical and nonclinical specimens.
Cat. no. P36 is not intended to be used for the diagnosis of human disease. |
|
K226
|
C Diff Banana Broth™, 16x100mm Tube, 10ml
|
20 tubes/box
|
Hardy Diagnostics C Diff Banana Broth™ is recommended as a selective enrichment broth for the culture and recovery of C. difficile from environmental samples.
This product is not intended to be used for the diagnosis of human disease. |
|
K258
|
BHI Broth with Ciprofloxacin, 10μg/ml, 13x100mm Glass Tube, 5ml
|
20 tubes/box
|
Hardy Diagnostics BHI Broth with Ciprofloxacin, 10μg/ml is a selective pre-enrichment broth for gram-negative microorganisms with reduced susceptibility to ciprofloxacin. Pre-enrichment with the broth is performed with a mixed population of microorganisms from a lab sample. Hardy Diagnostics MacConkey Agar with Ciprofloxacin, 10μg/ml is a companion product meant to act as a screening subculture medium for the selective isolation of non-susceptible Ciprofloxacin, gram-negative microorganisms. Concomitant cultures are necessary to recover microorganisms for identification, susceptibility testing, and epidemiological typing. A negative result does not preclude fluoroquinolone non-susceptible, gram-negative colonization. Culture results obtained from these products are not intended to guide therapy. |
|
K82
|
TSB, USP, 16x125mm Tube, 10ml
|
20 tubes/box
|
Hardy Diagnostics Tryptic Soy Broth is recommended for use as a general purpose medium for the isolation and cultivation of a wide variety of bacteria and fungi. The U.S. Pharmacopeia National Formulary (USP) describes its use for sterility testing.(1)
This product is not intended to be used for the diagnosis of human disease. |
|
L16
|
Triple Sugar Iron (TSI) Agar, 16x100mm Tube, 6ml Slant
|
20 tubes/box
|
Hardy Diagnostics Triple Sugar Iron (TSI) Agar is recommended for use in the differentiation of Enterobacteriaceae by their ability to ferment glucose, lactose, and sucrose, and their ability to produce hydrogen sulfide. |
|
L50
|
Triple Sugar Iron (TSI) Agar, 16x125mm Tube, 8ml Slant
|
20 tubes/box
|
Hardy Diagnostics Triple Sugar Iron (TSI) Agar is recommended for use in the differentiation of Enterobacteriaceae by their ability to ferment glucose, lactose, and sucrose, and their ability to produce hydrogen sulfide |
|
L57
|
LIM Broth, 13x100mm Tube, 5ml
|
20 tubes/box
|
Hardy Diagnostics LIM Broth is recommended for the selective enrichment of group B streptococci (Streptococcus agalactiae) from anovaginal specimens from pregnant women. |
|
L70
|
KIA Slant, 16x125mm Tube, 8ml Slant
|
20 or 100 tubes/box
|
Hardy Diagnostics Kligler Iron Agar (KIA) is recommended for use in differentiating certain members of the Enterobacteriaceae by demonstrating hydrogen sulfide production and the fermentation of dextrose and lactose. |
|
L80
|
Simmons Citrate Agar, 16x100mm Tube, 5.5ml Slant
|
20 tubes/box
|
Hardy Diagnostics Simmons Citrate Agar is recommended for use in the differentiation of gram-negative enteric bacilli based on citrate utilization. |
|
L225
|
ENTEROSCREEN 4™, 16X125MM TUBE, 4 LAYER SLANT, 12ML
|
20 tubes/box
|
Hardy Diagnostics EnteroScreen 4™ is recommended for screening of stool specimen isolates of non-lactosefermenting, oxidase-negative, enteric pathogens and the differentiation of Salmonella and Shigella to rule out normal enteric flora. |
|
ML05, ML1,ML2, ML3, ML4, ML5, ML6, ML7, or ML8
|
MCFARLAND LATEX STANDARDS
|
ML05 One tube/box, ML1 One tube/box, ML2 One tube/box, ML3 One tube/box, ML4 One tube/box, ML5 One tube/box, ML6 One tube/box, ML7 One tube/box, ML8 One tube/box
|
McFarland Latex Standards are used as turbidity standards for adjusting densities of bacterial suspensions.(ML05,ML1,ML2,ML3,ML4,ML5,ML6,ML7 OR ML8) |
|
PL030HD
|
StrepPRO™ Grouping Kit
|
60 tests/kit
|
Hardy Diagnostics StrepPRO™ Grouping Kit provides a rapid latex agglutination method for the serological
identification of Lancefield's groups A, B, C, D, F, and G from isolated colonies of beta-hemolytic Streptococcus spp. and Enterococcus faecalis. |
|
Q11
|
Motility Test Medium with TTC, 16x100mm Tube, 8ml Deep
|
20 tubes/box
|
Motility Test Medium with and without Triphenyltetrazolium Chloride (TTC) is recommended for the detection of motility in gram-negative enteric bacilli. TTC is added to enhance visualization of bacterial growth. |
|
Q58
|
TSA, USP, 20x125mm Tube, 18ml Deep
|
20 tubes/box
|
Hardy Diagnostics Tryptic Soy Agar (TSA), USP is recommended for use as a general growth medium for the
detection and enumeration of microorganisms from non-clinical samples (except G60, G60BX, and J330) as specified by the United States Pharmacopoeia (USP).(1) In addition, the medium complies with the harmonized European, U.S. and Japanese Pharmacopoeias for determining the microbial quality of non-sterile products.(1)
Cat. nos. H19, W64, Q38, Q80, U49, U60, U158, U260, U360, U361, and U373 products are not intended to be used for the diagnosis of human disease. |
|
R32
|
Triple Sugar Iron (TSI) Agar, 13x100mm Tube, 4ml Slant
|
20 tubes/box
|
Hardy Diagnostics Triple Sugar Iron (TSI) Agar is recommended for use in the differentiation of Enterobacteriaceae by their ability to ferment glucose, lactose, and sucrose, and their ability to produce hydrogen sulfide. |
|
R70
|
KIA Slant, 13x100mm Tube, 4.5ml Slant
|
20 or 100 tubes/box
|
Hardy Diagnostics Kligler Iron Agar (KIA) is recommended for use in differentiating certain members of the Enterobacteriaceae by demonstrating hydrogen sulfide production and the fermentation of dextrose and lactose. |
|
R75bx
|
FB Broth, 13x85mm Tube, 4m
|
100 tubes/box
|
Hardy Diagnostics FB (Fastidious Bacteria) Broth is used for the enrichment and cultivation of Neisseria spp., Haemophilus spp., Streptococcus spp., Corynebacterium spp. and other fastidious bacteria from clinical specimens. |
|
R99
|
Viral Transport Medium, tube, 3ml
|
20 tubes/box
|
Hardy Diagnostics Viral Transport Medium is recommended for the collection and transport of clinical specimens for the recovery of viral agents including, but not limited to, Herpes Simplex Type I, Herpes Simplex Type II, Cytomegalovirus (CMV), Influenza A, Influenza B, Respiratory Syncytial Virus (RSV), Echovirus, Adenovirus, etc. |
|
R201
|
Phosphate Buffered Saline (PBS), 13x100mm Tube, 1ml
|
20 tubes/box
|
Hardy Diagnostics Phosphate Buffered Saline (pH of 7.5) is recommended as a diluent for quantitative culturing or as a rinsing agent in microbiological, immunological, histological and molecular testing procedures. |
|
SRK30
|
EnviroTrans™ 0.85% Saline, 15x75mm Polyproplyene Tube with swab, 2ml
|
20 vials/box
|
Hardy Diagnostics EnviroTrans™ Saline, 0.85%, is designed for sampling surfaces as a part of HACCP (Hazard Analysis Critical Control Point) systems and other environmental monitoring testing. The EnviroTrans™ Saline, 0.85% packages everything needed to collect samples from work surfaces, utensils or other industrial apparatuses (i.e. pump impellers, gaskets, etc.).
This product is not intended to be used for the diagnosis of human disease. |
|
U38
|
TSB, USP/EP/JP, 20x125mm Tube, 15ml
|
20 tubes/box
|
Hardy Diagnostics Tryptic Soy Broth is recommended for use as a general purpose medium for the isolation and cultivation of a wide variety of bacteria and fungi. The U.S. Pharmacopeia National Formulary (USP) describes its use for sterility testing.(1)
This product is not intended to be used for the diagnosis of human disease. |
|
U101
|
Tryptic Soy Broth, USP, 100ml Serum Vial, 100ml
|
10 vials/box
|
ardy Diagnostics HardyVal™ à la carte products are recommended for routine use in the monitoring of aseptic procedures used in the preparation of Compounded Sterile Preparations (CSPs). HardyVal™ à la carte components can be purchased separately and used to create customized proficiency tests that most closely resemble the laboratory's procedures. In addition, Tryptic Soy Broth (TSB), also known as Soybean Casein Digest Broth, in HardyVal™ à la carte complies with the harmonized European, U.S. and Japanese Pharmacopoeias for determining the microbial quality of non-sterile products. (1)
These products are not intended to be used for the diagnosis of human disease. |
|
U109
|
Fluid A, USP, 100ml Serum Bottle, 100ml
|
20 bottles/box
|
Hardy Diagnostics USP Fluids A, D, and K are used by the pharmaceutical and medical device industry in
procedures used to ensure sterility of injectables, non-injectables, liquid products, oils and ointments, antibiotic powders, sterile pathway devices and aerosols.(1) |
|
U110
|
Fluid D, USP, 100ml Glass Bottle, 100ml
|
20 bottles/box
|
Hardy Diagnostics USP Fluids A, D, and K are used by the pharmaceutical and medical device industry in
procedures used to ensure sterility of injectables, non-injectables, liquid products, oils and ointments, antibiotic powders, sterile pathway devices and aerosols.(1) |
|
U348
|
Fluid K, USP, 500ml Glass Bottle with septum cap, 300ml
|
10 bottles/box
|
Hardy Diagnostics USP Fluids A, D, and K are used by the pharmaceutical and medical device industry in
procedures used to ensure sterility of injectables, non-injectables, liquid products, oils and ointments, antibiotic powders, sterile pathway devices and aerosols.(1) |
|
U382
|
Tryptic Soy Broth, USP, 20ml Serum Vial, 15ml
|
10 vials/box
|
Hardy Diagnostics HardyVal™ à la carte products are recommended for routine use in the monitoring of aseptic procedures used in the preparation of Compounded Sterile Preparations (CSPs). HardyVal™ à la carte components can be purchased separately and used to create customized proficiency tests that most closely resemble the laboratory's procedures. In addition, Tryptic Soy Broth (TSB), also known as Soybean Casein Digest Broth, in HardyVal™ à la carte complies with the harmonized European, U.S. and Japanese Pharmacopoeias for determining the microbial quality of non-sterile products. |
|
U513*
|
SP4 Broth with Urea, 500ml Polycarbonate Bottle, 500ml
|
1 each
|
Hardy Diagnostics SP4 Media are recommended for the isolation, differentiation and maintenance of mycoplasma, including M. hominis, M. pneumoniae, and Ureaplasma urealyticum.
*Bottle format not useful for clinical procedures. |
|
U8210
|
TSB, USP, 20ml Serum Vial, 10ml
|
50 vials/box
|
Hardy Diagnostics Tryptic Soy Broth is recommended for use as a general purpose medium for the isolation and cultivation of a wide variety of bacteria and fungi. The U.S. Pharmacopeia National Formulary (USP) describes its use for sterility testing.(1)
This product is not intended to be used for the diagnosis of human disease. |
|
W15
|
BHI Agar, 15x100mm Plate, 26ml
|
10 plates/bag
|
Hardy Diagnostics Brain Heart Infusion (BHI) Agar is a general purpose nutrient medium recommended for the cultivation and isolation of a variety of microorganisms, including bacteria, yeasts, and molds. The addition of defibrinated sheep blood and antimicrobics produces a selective medium used for the isolation of pathogenic fungi from specimens heavily contaminated with bacteria and saprophytic fungi. |
|
W30
|
Middlebrook 7H10 Agar, 15x100mm Plate, 26ml
|
10 plates/bag
|
Hardy Diagnostics Middlebrook 7H10 Agar is recommended for use in qualitative procedures for the isolation and cultivation of Mycobacterium species. |
|
W35
|
Middlebrook 7H11 Agar, 15x100mm Plate, 28ml
|
10 plates/bag
|
Hardy Diagnostics Middlebrook 7H11 Agar is recommended for use in the isolation and cultivation of
Mycobacterium species.(1,8) |
|
W87
|
Rose Bengal Agar with Chloramphenicol, 15x100mm Plate, 26ml
|
10 plates/bag
|
Hardy Diagnostics Rose Bengal Agar with Chloramphenicol is recommended for the selective isolation and
enumeration of fungi from environmental and food sources.
This product is not intended to be used for the diagnosis of human disease |
|
W169
|
BCYE Agar with GPVC, 15x100mm Plate, 26ml
|
10 plates/bag
|
Hardy Diagnostics Buffered Charcoal Yeast Extract (BCYE) Agar formulations are recommended for use in the cultivation and primary isolation of Legionella spp. in water and other samples suspected of harboring the bacteria. BCYE without Cysteine is for use in conjunction with BCYE Agar containing L-Cysteine for identification of Legionella spp. from clinical and environmental sources.
Cat. no. P251 is not intended to be used for the diagnosis of human disease. |
|
X52
|
Transgrow, 50ml HardyFlask™, 12ml
|
20 flasks/box
|
Modified Martin Lewis is a selective medium used in qualitative procedures for the isolation of Neisseria gonorrhoeae with suppression of most other gram-negative diplococci, gram-negative bacilli, gram-positive organisms and yeast.
The CO 2 enriched environment allows for the growth of pathogenic Neisseria spp. |
|
Z003
|
CoaguStaph™, Coagulase Plasma with EDTA
|
6 x 3ml
|
Hardy Diagnostics CoaguStaph™ is used to perform the coagulase test. The coagulase test is used for the
identification of Staphylococcus aureus. |
|
Z40
|
Strep B Carrot Broth™ One-Step, 13x100mm Tube, 4ml
|
20 tubes/box
|
Strep B Carrot Broth™ One-Step is a selective and differential medium which is intended for the detection of Group B Streptococcus (GBS) from anovaginal specimen collected from pregnant women. The medium is used as an aid in the qualitative determination of GBS colonization in pregnant women. The color change reaction from white to orange is representative of a positive result for presence of GBS. The medium requires 24 hours of incubation but positive results can be interpreted and reported as early as 16 hours. Due to the properties of Strep B Carrot Broth™ One-Step, non-hemolytic GBS cannot be detected by the medium’s color change and requires subculture for identification. Any presumptive negative indicated by lack of color change at the end of the incubation period must be subcultured to a non-selective medium (e.g., Tryptic Soy Agar with 5% Sheep Blood) to confirm absence of GBS. Subculture must also be performed to recover isolates for conducting susceptibility testing as recommended for penicillin-allergic women. |
|
Z46BX
|
Strep B Carrot Broth™ One-Step, 16x100mm Tube, 6ml
|
100 tubes/box
|
Strep B Carrot Broth™ One-Step is a selective and differential medium which is intended for the detection of Group B Streptococcus (GBS) from anovaginal specimen collected from pregnant women. The medium is used as an aid in the qualitative determination of GBS colonization in pregnant women. The color change reaction from white to orange is representative of a positive result for presence of GBS. The medium requires 24 hours of incubation but positive results can be interpreted and reported as early as 16 hours. Due to the properties of Strep B Carrot Broth™ One-Step, non-hemolytic GBS cannot be detected by the medium’s color change and requires subculture for identification. Any presumptive negative indicated by lack of color change at the end of the incubation period must be subcultured to a non-selective medium (e.g., Tryptic Soy Agar with 5% Sheep Blood) to confirm absence of GBS. Subculture must also be performed to recover isolates for conducting susceptibility testing as recommended for penicillin-allergic women. |
|
Z56
|
AFB Smear Fix
|
15ml
|
Hardy Diagnostics AFB Smear Fix is designed to assist in acid-fast staining of positive mycobacteria cultures from the 12B culture vials used in Becton Dickinson's BACTEC™ Automated Culture System. |
|
Z74
|
UriStain™, Urine Sediment Stain
|
15ml
|
Hardy Diagnostics UriStain™ is intended for use in sediment staining of urine specimens. |
|
Z80
|
Mineral Oil, Heavy Grade
|
150ml
|
Hardy Diagnostics Mineral Oil is used as a sealant to create an anaerobic environment for biochemical tests such as decarboxylase and oxidation and fermentation reactions. These products are not for use in surgical or patient applications. These Mineral Oils are strictly for laboratory use. |
|
Z87
|
Flagella Stain, 0.5oz. Polyethylene Dropper Bottle, 15ml
|
1 bottle
|
Hardy Diagnostics Flagella Stain is recommended for use in detecting the presence and arrangement of flagella on the bacterial cell. |
|
Z93
|
OxiStrips™ Oxidase Strips
|
25 strips/vial
|
Hardy Diagnostics OxiStrips™ Oxidase Strips and OxiSticks™ Oxidase Swabs are used for the detection of
cytochrome oxidase activity in bacteria. |
|
Z98
|
CarboFerm™ Neisseria Kit
|
24 tests/kit
|
Hardy Diagnostics CarboFerm™ Neisseria Kit is a rapid test (four hour) for the identification of Neisseria species (including N. gonorrhoeae and N. meningitidis) and Moraxella ( Branhamella ) catarrhalis. CarboFerm™ uses acid production from carbohydrates and the presence of butyrate esterase to differentiate and identify Neisseriaspecies and M. catarrhalis. |
|
Z110
|
CatScreen™
|
25 tests/kit
|
Hardy Diagnostics CatScreen™ is a rapid test for the detection of the enzyme butyrate esterase in bacteria isolated on culture media for the presumptive identification of Moraxella (Branhamella) catarrhalis. |
|
Z111
|
Indoxyl Acetate Disks
|
25 disks/vial
|
HardyDisk™ Indoxyl Acetate Disks are used to determine the ability of certain bacteria to hydrolyze indoxyl acetate. Indoxyl Acetate Disks can be helpful in the rapid identification and differentiation of Campylobacter, Helicobacter, and Wolinella species. |
|
Z112
|
Lysostaphin Differentiation Disks
|
50 disks/vial
|
HardyDisk™ Lysostaphin Differentiation Disks are used to rapidly differentiate Staphylococcus spp. and Micrococcus spp. based on lysostaphin resistance. |
|
Z130
|
MucoGest™ 50, 250mg
|
20 tubes/box
|
Hardy Diagnostics MucoGest™ is composed of dithiothreitol, a mucolytic agent recommended for use in the
digestion and decontamination procedures of sputum and other clinical specimens for the recovery of mycobacteria and fungi. |
|
Z131
|
MucoGest™ 100, 500mg
|
20 tubes/box
|
Hardy Diagnostics MucoGest™ is composed of dithiothreitol, a mucolytic agent recommended for use in the
digestion and decontamination procedures of sputum and other clinical specimens for the recovery of mycobacteria and fungi. |
|
Z132
|
Alkaline Phosphatase Kit
|
125 tests/kit
|
Hardy Diagnostics Alkaline Phosphatase Kit is recommended for confirmation of successful pasteurization in milk, butter, cream and cheese, using the Rutgers method.(1)
This product is not intended to be used for the diagnosis of human disease. |
|
Z206
|
CAMP Spot Test Reagent, 2ml Cryogenic Vial, 1ml Fill
|
20 vials/box
|
Hardy Diagnostics CAMP Spot Test Reagent is used to rapidly determine an organism's ability to produce the protein CAMP factor. CAMP factor is a diffusible, extracellular protein which acts synergistically with staphylococcal beta-hemolysin (beta-lysin). The test is particularly useful as part of the identification of Streptococcus agalactiae (group B streptococci), and Listeria monocytogenes. |
|
Z306
|
Beta Toxin
|
25ml
|
Hardy Diagnostics Beta Toxin is used to detect the presence of the CAMP factor gene which aids in the
presumptive identification of Streptococcus agalactiae from bovine samples.
This product is not intended to be used for the diagnosis of human disease. |
|
Z7011
|
Optochin Differentiation Disks
|
1 x 50 disks/cartridge
|
Hardy Diagnostics Optochin Differentiation Disks are recommended for use in the presumptive identification of Streptococcus pneumoniae from other alpha-hemolytic streptococci. |
|
Z7031
|
X-Factor
|
1x50 disks/cartridge
|
Hardy Diagnostics X - and V-Factor Disks are paper disks impregnated with X (hemin) and V (nicotinamide
adenine dinucleotide - NAD) growth factors. They are used for the differentiation of Haemophilus species, including Aggregatibacter aphrophilus based upon their requirements for the growth factors. |
|
Z7041
|
V-Factor
|
1x50 disks/cartridge
|
Hardy Diagnostics X - and V-Factor Disks are paper disks impregnated with X (hemin) and V (nicotinamide
adenine dinucleotide - NAD) growth factors. They are used for the differentiation of Haemophilus species, including Aggregatibacter aphrophilus based upon their requirements for the growth factors. |
|
Z7051
|
XV-Factor
|
1x50 disks/cartridge
|
Hardy Diagnostics X - and V-Factor Disks are paper disks impregnated with X (hemin) and V (nicotinamide
adenine dinucleotide - NAD) growth factors. They are used for the differentiation of Haemophilus species, including Aggregatibacter aphrophilus based upon their requirements for the growth factors. |
|
Z9335
|
HARDYDISK™ ANTIMICROBIAL SENSITIVITY TEST (AST)
|
|
HardyDisk™ AST Disks are used for semi-quantitative in vitro susceptibility testing by the agar diffusion test procedure (KirbyBauer) of rapidly growing and certain fastidious bacterial pathogens. Standardized methods for agar diffusion testing have been described for Enterobacteriaceae, Staphylococcus spp., Pseudomonas spp., Acinetobacter spp., Listeria monocytogenes, Enterococcus spp., and by modified procedures, Haemophilus spp., Neisseria gonorrhoeae, N. meningitidis and Streptococcus spp., including Streptococcus pneumoniae. |
|
X19
|
HardyFlask™ Lowenstein Jensen (LJ) Medium with Pyruvate, 12ml Fill
|
20 flasks/box
|
Hardy Diagnostics Lowenstein Jensen Media are recommended for use in the cultivation and isolation of
Mycobacterium species. |
|
DVEB00151
|
BactoReal® Kit Mycoplasma hyopneumoniae
|
50 Tests/Kit or 100 Tests/Kit
|
BactoReal® Kit Mycoplasma hyopneumoniae is a real-time PCR assay for detection of M. hyopneumoniae DNA.
This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. hyopneumoniae from samples purified from lung biopsies or bronchoalveolar lavages (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB00251
|
BactoReal® Kit Mycoplasma synoviae
|
50 Tests/Kit or 100 Tests/Kit
|
BactoReal® Kit Mycoplasma synoviae is a real-time PCR assay for detection of M. synoviae DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. synoviae from samples purified from faecal samples, or swabs of tissues, exudates, diluted tissue homogenates, aspirates from the infraorbital sinuses or joint cavities, as well as material from egg yolk or embryos. Mycoplasma synoviae DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from swabs using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB00351
|
BactoReal® Kit Mycoplasma gallisepticum
|
50 Tests/Kit or 100 Tests/Kit
|
BactoReal® Kit Mycoplasma gallisepticum is a real-time PCR assay for detection of M. gallisepticum DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Applied Biosystems),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. gallisepticum from samples purified from faecal samples, or swabs of tissues, exudates, diluted tissue homogenates, aspirates from the infraorbital sinuses or joint cavities, as well as from material from egg yolk or embryos. Mycoplasma gallisepticum DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from swabs using the QIAamp DNA Mini Kit extraction methods, for example. Mycoplasma imitans is not detected by this test. |
|
RTB25F
|
biotical FOB Card
|
25 test without positive or negative controls.
|
biotical FOB card is a coloured chromatographic immunoassay test (qualitative cut off test) for the detection of Human Hemoglobin (hHb) in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to detect faecal occult blood (gastrointestinal bleeding) in the lower digestive tract. |
|
RTB25TF
|
biotical TRANSFERRIN Card
|
25 test without positive or negative controls.
|
biotical Transferrin card is a coloured chromatographic immunoassay test (qualitative cut-off test) for the determination of human transferrin (hTf) in stool samples. biotical Transferrin card offers a simple, a highly sensitive and non-invasive screening assay to make a presumptive diagnosis of gastrointestinal bleeding. |
|
RTB25FT
|
biotical FOB+Transferrin Card
|
25 test without positive or negative controls.
|
biotical FOB + Transferrin card is a colored chromatographic immunoassay test (qualitative cut off test) for the simultaneous detection of Human Hemoglobin (hHb) and Human Transferrin (hTf) in stool samples.
Thanks to its easy handling and high sensitivity, the healthcare professional will be able to detect
fecal occult blood (gastrointestinal bleeding) in lower and/or upper digestive tract. |
|
RTB25CP
|
biotical Calprotectin Card
|
25 test without positive or negative controls.
|
biotical Calprotectin card is a colored chromatographic immunoassay test (qualitative cut off test) for the detection of human Calprotectin (hCp) in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Inflammatory Bowel Diseases (IBD) as well as a follow up of the treatment and to predict the risk of relapse. |
|
RTB25LT
|
biotical Lactoferrin Card
|
25 test without positive or negative controls.
|
biotical Lactoferrin card is a colored chromatographic immunoassay test (qualitative cut off test) for the detection of human Lactoferrin (hLf) in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Inflammatory Bowel Diseases (IBD) as well as a follow up of the treatment and to predict the risk of relapse. |
|
RTB25CL
|
biotical Calprotectin + Lactoferrin Card
|
25 test without positive or negative controls.
|
biotical Calprotectin + Lactoferrin card is a colored chromatographic immunoassay test (qualitative cut off test) for the simultaneous detection of Human Calprotectin (hCp) and Human Lactoferrin (hLf) in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis and detect gastrointestinal inflammation present in various pathologies. |
|
RTB25R
|
biotical Rotavirus Card
|
25 test without positive or negative controls.
|
biotical Rotavirus card is a colored chromatographic immunoassay test for the qualitative detection of
Rotavirus antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare
professional will be able to make a presumptive diagnosis of Rotavirus infection. |
|
RTB25AD
|
biotical Adenovirus Card
|
25 test without positive or negative controls.
|
biotical Adenovirus card is a coloured chromatographic immunoassay test for the qualitative detection of
Adenovirus antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare
professional will be able to make a presumptive diagnosis of Adenovirus infection. |
|
RTB25RA
|
biotical Rotavirus + Adenovirus Card
|
25 test without positive or negative controls.
|
biotical Rotavirus + Adenovirus card is a colored chromatographic immunoassay test for the simultaneous
qualitative detection of Rotavirus and Adenovirus antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Rotavirus and/or Adenovirus infection. |
|
RTB25AT
|
biotical Astrovirus Card
|
25 test without positive or negative controls.
|
biotical Astrovirus card is a colored chromatographic immunoassay test for the qualitative detection of
Astrovirus antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare
professional will be able to make a presumptive diagnosis of Astrovirus infection. |
|
RTB25NV
|
biotical Norovirus GI+GII Card
|
25 test without positive or negative controls.
|
biotical Norovirus GI+GII card is a rapid immunochromatography test for the qualitative simultaneous
detection of Norovirus genogroups I and II (GI and GII) in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional is able to make a presumptive diagnosis of Norovirus infection. |
|
RTB25EV
|
biotical Enterovirus Card
|
25 test without positive or negative controls.
|
biotical Enterovirus card is a colored chromatographic immunoassay test for the qualitative detection of
Enterovirus antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare
professional will be able to make a presumptive diagnosis of Enterovirus infection. |
|
RTB25E
|
biotical E. Coli O157:H7 Card
|
25 test without positive or negative controls.
|
biotical E. coli O157:H7 card is a rapid immunochromatography test for the qualitative detection of
Escherichia coli O157:H7 (E. coli O157:H7) in stool samples and suspicious colonies of E. coli O157:H7 in stool culture. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of infection caused by E. coli O157:H7 and could be used for the
identification of suspected isolates of E. coli O157:H7 from a selective medium (stool culture). |
|
RTB25CA
|
biotical Campylobacter Card
|
25 test without positive or negative controls.
|
biotical Campylobacter card is a colored chromatographic immunoassay test for the qualitative detection of Campylobacter in stool samples and suspicious colonies of Campylobacter in culture. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Campylobacter infection and could be used to identify suspected Campylobacter isolates from selective media (stool culture). |
|
RTB25SA
|
biotical Salmonella Card
|
25 test without positive or negative controls.
|
biotical Salmonella card is a rapid immunochromatography test for the qualitative detection of Salmonella antigens in stool samples and suspicious colonies of Salmonella in stool culture. Thanks to its easy handling and high sensitivity, the healthcare professional is able to make a presumptive diagnosis of Salmonella infection (salmonellosis) and it could be used to identify suspected Salmonella isolates from a selective medium (stool culture). |
|
RTB25ST
|
biotical Salmonella typhi Card
|
25 test without positive or negative controls.
|
biotical Salmonella typhi card is a coloured chromatographic immunoassay test for the qualitative detection of Salmonella typhi in stool samples and Salmonella typhi suspected colonies in stool culture. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Salmonella typhi infection and it could be used to identify suspected Salmonella typhi isolates from selective media (stool culture). |
|
RTB25SP
|
biotical Salmonella paratyphi Card
|
25 test without positive or negative controls.
|
biotical Salmonella paratyphi card is a coloured chromatographic immunoassay test for the qualitative
detection of Salmonella paratyphi in stool samples and Salmonella paratyphi suspected colonies in stool
culture. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Salmonella paratyphi infection and it could be used to identify suspected Salmonella paratyphi isolates from selective media (stool culture). |
|
RTB25PG
|
biotical H. pylori Card
|
25 test without positive or negative controls.
|
biotical H. pylori card is a rapid immunochromatography test for the qualitative detection of Helicobacter pylori antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional can make a presumptive diagnosis to detect Helicobacter pylori. |
|
RTB25GD
|
biotical Clostridium difficile GDH Card
|
25 test without positive or negative controls.
|
biotical Clostridium difficile GDH card is a rapid immunochromatography test for the qualitative detection of the enzyme glutamate dehydrogenase (GDH) Clostridium difficile in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a simple diagnosis and detect the possible presence of Clostridium difficile in infected people. |
|
RTB25CD
|
biotical Clostridium difficile toxins A+B Card
|
25 test without positive or negative controls.
|
biotical Clostridium difficile Toxins A+B card is a colored chromatographic immunoassay test for the qualitative detection of Clostridium difficile Toxin A and B in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional can make a simple diagnosis and detect the possible presence of toxigenic strains of Clostridium difficile in infected people. |
|
RTB25Y3
|
biotical Yersinia Enterocolitica O:3 Card
|
25 test without positive or negative controls.
|
biotical Yersinia enterocolica O:3 card is a coloured chromatographic immunoassay test for the qualitative detection of Yersinia enterocolica O:3 in stool samples and Yersinia enterocolica O:3 suspected colonies in stool culture. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Yersinia enterocolica O:3 infection and it could be used to identify suspected Yersinia enterocolica O:3 isolates from selective media (stool culture). |
|
RTB25Y9
|
biotical Yersinia enterocolitica O:9 Card
|
25 test without positive or negative controls.
|
biotical Yersinia enterocolica O:9 card is a coloured chromatographic immunoassay test for the qualitative detection of Yersinia enterocolica O:9 in stool samples and Yersinia enterocolica O:9 suspected colonies in stool culture. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of Yersinia enterocolica O:9 infection and it could be used to identify suspected Yersinia enterocolica O:9 isolates from selective media (stool culture). |
|
RTB25G
|
biotical Giardia Card
|
25 test without positive or negative controls.
|
biotical Giardia Card is a colored chromatographic immunoassay test for the qualitative detection of Giardia antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of giardiasis. |
|
RTB25K
|
biotical CRYPTO Card
|
25 test without positive or negative controls.
|
biotical CRYPTO card is a colored chromatographic immunoassay test for the qualitative detection of
Cryptosporidium antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive diagnosis of criptosporosis. |
|
RTB25KG
|
biotical Crypto + Giardia Card
|
25 test without positive or negative controls.
|
biotical Crypto+Giardia card is a colored chromatographic immunoassay test for the simultaneous
qualitative detection of Cryptosporidium and Giardia antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional will be able to make a presumptive
diagnosis of criptosporosis and/or Giardiasis. |
|
RTB25EH
|
biotical Entamoeba Card
|
25 test without positive or negative controls.
|
biotical Entamoeba card is a rapid immunochromatography test for the qualitative detection of Entamoeba
histolytica and Entamoeba dispar antigens in stool samples. Thanks to its easy handling and high sensitivity, the healthcare professional can make a presumptive diagnosis of amebiasis. |
|
RTB25SC
|
biotical Strep A Card (+PC)
|
25 test without positive or negative controls.
|
biotical Strep A card is a rapid immunochromatography test for the qualitative detection of Group A
Streptococcus antigens (GAS) in throat swab samples and culture of isolated colonies suspected of Group A Streptococcus. Thanks to its easy handling and high sensitivity, the healthcare professional is able to make a presumptive diagnosis of respiratory infection caused by GAS. |
|
RTB25RVC
|
biotical RSV Card (+PC)
|
25 test with positive control, without negative control
|
biotical RSV card is a rapid immunochromatography test for the qualitative detection of Respiratory Syncytial Virus (RSV) antigens in nasal swab sample, or through nasopharyngeal washing or nasopharyngeal aspirate. Thanks to its easy handling and high sensitivity, the healthcare professional is able to make a presumptive diagnosis of infections caused by RSV. |
|
RTB25APC
|
biotical Adeno. Resp. Card (+PC)
|
25 test with positive control, without negative control.
|
biotical Adenovirus Respiratory card is a rapid immunochromatography test for the qualitative detection of Adenovirus antigens in nasal swab, washed or nasopharyngeal aspirate samples. Thanks to its easy
handling and high sensitivity, the healthcare professional is able to make a presumptive diagnosis of infection caused by Adenovirus. |
|
RTB25VRC
|
biotical RSV+Adenovirus Respiratory Card (+PC)
|
25 tests with positive control, without negative control.
|
biotical RSV + Adeno Respiratory card is a rapid immunochromatography test for the simultaneous
qualitative detection of Respiratory Syncytial Virus (RSV) and Respiratory Adenovirus antigens in
nasopharyngeal swab samples. Thanks to its easy handling and high sensitivity, the healthcare profesional are able to make a presumptive diagnosis of infection caused by RSV and / or Respiratory Adenovirus. |
|
RTB25ABC
|
biotical Influenza A+B Card (+PC)
|
25 tests with positive control, without negative control.
|
biotical Influenza A+B card is a rapid immunochromatography test for the qualitative simultaneous detection of Influenza A and Influenza B antigens from nasal swab, nasopharyngeal wash or aspirate specimens. Thanks to its easy handling and high sensitivity, the healthcare professional can make a presumptive diagnosis of infection caused by Influenza A and / or Influenza B. |
|
RTB25COV2C
|
biotical SARS COV-2 Ag Card (+PC)
|
25 tests with positive control, without negative control.
|
The biotical SARS-CoV-2 Ag card is a rapid immunochromatography test for the qualitative detection of the structural nucleoprotein antigen (N protein) of the SARS-CoV-2 coronavirus, from nasopharyngeal swab
samples and nasal swabs samples from patients with suspected infection. by COVID-19.
Thanks to its easy handling and high sensitivity, the health professional or the layman in the field will be able to make a presumptive diagnosis of infection caused by the SARS-CoV-2 coronavirus. |
|
RTB25SNCN
|
biotical S. PNEUMONIAE Card (+PC +NC)
|
25 test with positive and negative control.
|
biotical S. pneumoniae card is a colored chromatographic immunoassay test for the qualitative detection of Streptococcus of the subspecies pneumoniae in urine samples. Thanks to its easy handling and high
sensitivity, the healthcare professional will be able to make a presumptive diagnosis of pneumonia in infected persons. |
|
RTB25LPCN
|
biotical Legionella Card (+PC +NC)
|
25 tests with positive and negative control.
|
biotical Legionella card is a rapid immunochromatography test for the qualitative detection of Legionella pneumophila serogroup 1 in urine samples. Thanks to its easy handling and high sensitivity, the healthcare professional can make a presumptive diagnosis of Legionellosis in infected humans. |
|
RTB25LPCN-1
|
GEN-C 2.0
|
24 TESTS
|
Gen-C 2.0 is an in vitro line probe assay for the genotyping of hepatitis C virus. The assay discriminates between HCV genotypes on the basis of variations in the 5’ UTR and Core regions. The assay works with amplicons obtained with NLM code AA896/24. For optimal results it is strictly recommended to use samples with viral load between 2x103 and 1x107 (if necessary dilute high viral load plasma before the RNA extraction). |
|
1370S
|
Petri Plate Can, Stainless Steel, Holds 15, 100x10mm Plates
|
Eaches
|
Petri Plate Can, Stainless Steel, Holds 15, 100x10mm Plates. |
|
370013
|
RDE II (Receptor Destroying Enzyme), Haemagglutination Test for Influenza, 20ml x 5 vials
|
Eaches
|
RDE(Receptor Dest.Enzyme) Denka Seiken, 20mlx5 RU R. |
|
BST20
|
SporAmpule® Liquid Biological Indicator, for Steam Sterilization
|
Eaches
|
An error-free, BI (Biological Indicator) system certified for use with steam sterilization processes. After processing in a normal load, the SporAmpule® is incubated at 55°C to 60°C for 48 hours. A purple to yellow color change and visible turbidity of a processed SporAmpule® indicates sterilizer failure. |
|
C5511
|
CRITERION™ Cystine Tryptic Agar Base, Dehydrated Culture Media, 500gm Wide-Mouth Bottle
|
Each
|
Hardy Diagnostics CRITERION™ Cystine Tryptic Agar (CTA) is recommended for the determination of carbohydrate fermentation by fastidious microorganisms, such as Neisseria spp. It is also used for the detection of bacterial motility and the base can serve as a holding medium for the maintenance of fastidious microorganisms. |
|
C5850
|
CRITERION™ Hemoglobin Powder, Dehydrated Culture Media, Mylar™ Zip-Pouch for 2L
|
Each
|
Hardy Diagnostics CRITERION™ Hemoglobin Powder is used as a supplement for GC Agar Base in the preparation of Chocolate Agar. Chocolate Agar is used to cultivate fastidious organisms such as Neisseria spp. and Haemophilus spp. |
|
C6810
|
CRITERION™ Sabouraud Dextrose Agar (SabDex), Dehydrated Culture Media, Mylar™ Zip-Pouch for 2L
|
Each
|
Hardy Diagnostics CRITERION™ Sabouraud Dextrose Agar is recommended for the isolation, cultivation, and
maintenance of non-pathogenic and pathogenic species of fungi and yeasts. |
|
D590
|
DiluLok™, Butterfield’s Buffer, 90ml Fill, Dilution Bottle with Hinged Flip Top
|
50 vials/case
|
Hardy Diagnostics Butterfield's Phosphate Buffer is used as a diluent for the preparation of dilutions in plate count and other laboratory processes.
This product is not intended to be used for the diagnosis of human disease. |
|
DURA60
|
DuraRack®, metal Petri Plate Rack, for 15x100mm Plates, holds 60 Plates
|
Each
|
The DuraRack™ is a durable, autoclavable, heavy gauge coated steel wire rack that allows for
easy loading and unloading of Petri or contact plates. Its sturdy welded design and long-lasting
protective coating provides a culture media plate rack that will withstand the test of time. |
|
G21
|
SP4 Agar with Glucose, for Mycoplasma
|
10 plates/bag
|
Hardy Diagnostics SP4 Media are recommended for the isolation, differentiation and maintenance of mycoplasma, including M. hominis, M. pneumoniae, and Ureaplasma urealyticum.
*Bottle format not useful for clinical procedures. |
|
G335
|
HardyCHROM™ Bcc, 15x100mm Plate, 22ml
|
10 plates/bag
|
Hardy Diagnostics HardyCHROM™ Bcc is recommended for the selective isolation and differentiation of
Burkholderia cepacia and other members of the Bcc group based on colony color. The medium is useful for testing non-sterile, water-based pharmaceuticals. Some ingredients are very light sensitive. Store and incubate media in the dark.
This product is not intended to be used for the diagnosis of human disease. |
|
G337
|
HardyCHROM™ Group A Strep, Chromogenic Medium, 15x100mm Plate
|
10 plates/bag
|
Hardy Diagnostics HardyCHROM™ Group A Strep Agar is a chromogenic medium recommended for the selective
cultivation and differential isolation of Group A Streptococcus (S. pyogenes) from specimens based on colony color. |
|
G343
|
HardyCHROM™ Candida + auris, 15x100mm Plate, 18ml
|
10 plates/bag
|
Hardy Diagnostics HardyCHROM™ Candida + auris is recommended as a medium for the primary, selective isolation and differential identification of Candida species. The medium allows for the differentiation of C. albicans, C. tropicalis, C. krusei, and C. auris based on colony morphology, color, and positive UV fluorescence. |
|
K109
|
Butterfield’s Phosphate Buffer, 9ml Fill, 16x125mm Glass Tube
|
20 tubes/box
|
Hardy Diagnostics Butterfield's Phosphate Buffer is used as a diluent for the preparation of dilutions in plate count and other laboratory processes.
This product is not intended to be used for the diagnosis of human disease. |
|
K31
|
FB Broth, 16x125mm Tube, 10m
|
20 tubes/box
|
Hardy Diagnostics FB (Fastidious Bacteria) Broth is used for the enrichment and cultivation of Neisseria spp., Haemophilus spp., Streptococcus spp., Corynebacterium spp. and other fastidious bacteria from clinical specimens. |
|
L65
|
Urea Agar, 16x100mm Tube, 5.5ml Slant
|
20 or 100 tubes/box
|
Hardy Diagnostics Urea Agar is recommended for use in the detection of urea hydrolysis in gram-negative organisms. |
|
SS9225
|
MycoSeal™, 500ml jar
|
60 shrink seals/jar
|
Hardy Diagnostics MycoSeal™ cellulose shrink seals are recommended for sealing 15x100mm petri plates. |
|
U100
|
Tryptic Soy Broth, Media Bag™, USP, 100ml
|
10 bags/box
|
Hardy Diagnostics HardyVal™ à la carte products are recommended for routine use in the monitoring of aseptic procedures used in the preparation of Compounded Sterile Preparations (CSPs). HardyVal™ à la carte components can be purchased separately and used to create customized proficiency tests that most closely resemble the laboratory's procedures. In addition, Tryptic Soy Broth (TSB), also known as Soybean Casein Digest Broth, in HardyVal™ à la carte complies with the harmonized European, U.S. and Japanese Pharmacopoeias for determining the microbial quality of non-sterile products.(1)
These products are not intended to be used for the diagnosis of human disease. |
|
W40
|
Middlebrook 7H11 Selective Agar, 15x100mm Plate, 28ml
|
10 plates/bag
|
Hardy Diagnostics Middlebrook 7H11 Agar is recommended for use in the isolation and cultivation of Mycobacterium species. |
|
Y57
|
OF Dextrose, 13x100mm Tube, 3ml
|
20 or 100 tubes/box
|
Hardy Diagnostics OF Basal Medium is recommended for the detection of oxidation or fermentation of carbohydrates by bacteria. |
|
Z44BX
|
Strep B Carrot Broth™ One-Step, 12x80mm Tube, 4ml
|
100 tubes/box
|
Strep B Carrot Broth™ One-Step is a selective and differential medium which is intended for the detection of Group B Streptococcus (GBS) from anovaginal specimen collected from pregnant women. The medium is used as an aid in the qualitative determination of GBS colonization in pregnant women. The color change reaction from white to orange is representative of a positive result for presence of GBS. The medium requires 24 hours of incubation but positive results can be interpreted and reported as early as 16 hours. Due to the properties of Strep B Carrot Broth™ One-Step, non-hemolytic GBS cannot be detected by the medium’s color change and requires subculture for identification. Any presumptive negative indicated by lack of color change at the end of the incubation period must be subcultured to a non-selective medium (e.g., Tryptic Soy Agar with 5% Sheep Blood) to confirm absence of GBS. Subculture must also be performed to recover isolates for conducting susceptibility testing as recommended for penicillin-allergic women. |
|
A188
|
Bovine Blood Agar, 15x100mm Plate, 17ml
|
10 plates/bag
|
Hardy Diagnostics Bovine Blood Media is recommended as a general purpose growth media for the cultivation, selective isolation, and differentiation of organisms responsible for mastitis in dairy populations.
This product is not intended to be used for the diagnosis of human disease. |
|
A189
|
Bovine Blood Agar with Esculin, 15x100mm Plate, 17ml
|
10 plates/bag
|
Hardy Diagnostics Bovine Blood Media is recommended as a general purpose growth media for the cultivation, selective isolation, and differentiation of organisms responsible for mastitis in dairy populations.
This product is not intended to be used for the diagnosis of human disease. |
|
C32
|
Middlebrook 7H9 Broth, 16x125mm Tube, 10ml
|
20 tubes/box
|
Hardy Diagnostics Middlebrook 7H9 Broth and Middlebrook 7H9 Broth with Tween® 80 are recommended for use in the cultivation of Mycobacterium spp. The media are also used for preparing dilutions of mycobacteria for antimicrobial testing.
Cat. no. U32 is not intended to be used for the diagnosis of human disease. |
|
C7521
|
CRITERION™ Mueller Hinton Broth
|
500gm
|
Hardy Diagnostics CRITERION™ Mueller Hinton Broth is recommended for use in the cultivation of a wide variety of microorganisms. Mueller Hinton Broth is also recommended for antimicrobial susceptibility testing of aerobicmicroorganisms by broth dilution methods.(7)
This dehydrated culture medium is a raw material intended to be used in the making of prepared media products, which will require further processing, additional ingredients, or supplements. |
|
CSM100
|
CryoSaver™, Skim Milk, 2ml Cryogenic Vial, 1.3 – 1.7ml Fill
|
100 vials/box
|
Hardy Diagnostics CryoSaver™, Skim Milk Media is recommended for the preservation of microorganisms by
freezing.
This product is not intended to be used for the diagnosis of human disease. |
|
MT016
|
Trichrome Blue Stain, Modified
|
One 16oz.
bottle/package
|
Hardy Diagnostics Trichrome Stain products are used in the differentiation and staining of intestinal parasites. These products may also be used as a counterstain in histological sections when performing the Gomori procedure. |
|
SV20
|
20ml Serum Vial, Empty
|
10 vials/box
|
Hardy Diagnostics HardyVal™ à la carte products are recommended for routine use in the monitoring of aseptic procedures used in the preparation of Compounded Sterile Preparations (CSPs). HardyVal™ à la carte components can be purchased separately and used to create customized proficiency tests that most closely resemble the laboratory's procedures. In addition, Tryptic Soy Broth (TSB), also known as Soybean Casein Digest Broth, in HardyVal™ à la carte complies with the harmonized European, U.S. and Japanese Pharmacopoeias for determining the microbial quality of non-sterile products.(1)
These products are not intended to be used for the diagnosis of human disease. |
|
X22
|
Lowenstein Jensen, 50ml Hardy Flask™, Slant
|
20 flasks/box
|
Hardy Diagnostics Lowenstein Jensen Media are recommended for use in the cultivation and isolation of
Mycobacterium species. |
|
Z61
|
Bile Spot Reagent
|
15ml
|
Hardy Diagnostics Bile Spot Reagent is recommended for use in presumptively differentiating bile-soluble
Streptococcus pneumoniae from bile-insoluble alpha-hemolytic Streptococcus spp. The bile solubility test may be performed using a cell suspension or by applying the Bile Spot Reagent directly to the colony. |
|
Z9075
|
HARDYDISK™ ANTIMICROBIAL SENSITIVITY TEST (AST)
|
5 cartridges, 50 disks
|
HardyDisk™ AST Disks are used for semi-quantitative in vitro susceptibility testing by the agar diffusion test procedure (KirbyBauer) of rapidly growing and certain fastidious bacterial pathogens. Standardized methods for agar diffusion testing have been described for Enterobacteriaceae, Staphylococcus spp., Pseudomonas spp., Acinetobacter spp., Listeria monocytogenes, Enterococcus
spp., and by modified procedures, Haemophilus spp., Neisseria gonorrhoeae, N. meningitidis and Streptococcus spp., including Streptococcus pneumoniae. |
|
DHUV02353
|
ViroReal® Kit SARS-CoV-2 & SARS
|
50 Test/Kit
|
ViroReal® Kit SARS-CoV-2 & SARS is an in vitro diagnostic test, based on one-step reverse transcription
real-time PCR, for the detection of the N gene of SARS-CoV-2 and SARS-CoV. The kit allows rapid and
sensitive detection of RNA of SARS-CoV-2 and SARS-CoV in samples purified from the respiratory tract. |
|
DVEB00153
|
BactoReal® Kit Mycoplasma hyopneumoniae
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma hyopneumoniae is a real-time PCR assay for detection of M. hyopneumoniae DNA.
This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. hyopneumoniae from samples purified from lung biopsies or bronchoalveolar lavages (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB00253
|
BactoReal® Kit Mycoplasma synoviae
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma synoviae is a real-time PCR assay for detection of M. synoviae DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. synoviae from samples purified from faecal samples, or swabs of tissues, exudates, diluted tissue homogenates, aspirates from the infraorbital sinuses or joint cavities, as well as material from egg yolk or embryos. Mycoplasma synoviae DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from swabs using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB00353
|
BactoReal® Kit Mycoplasma gallisepticum
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma gallisepticum is a real-time PCR assay for detection of M. gallisepticum DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Applied Biosystems),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. gallisepticum from samples purified from faecal samples, or swabs of tissues, exudates, diluted tissue homogenates, aspirates from the infraorbital sinuses or joint cavities, as well as from material from egg yolk or embryos. Mycoplasma gallisepticum DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from swabs using the QIAamp DNA Mini Kit extraction methods, for example. Mycoplasma imitans is not detected by this test. |
|
DVEB00453
|
BactoReal® Kit Haemophilus parasuis
|
50 Test/Kit
|
BactoReal® Kit Haemophilus parasuis is a real-time PCR assay for detection of H. parasuis (newly classified as Glaesserella parasuis) DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other realtime PCR instruments. This test allows the rapid and sensitive detection of DNA of H. parasuis from samples purified from biopsies (e.g. lung, heart, meninges), as well as from synovial fluid, pleural fluid, pericardial fluid, peritoneal fluid, or cerebrospinal fluid (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB00553
|
BactoReal® Kit Leptospira spp. (16S rDNA)
|
50 Test/Kit
|
BactoReal® Kit Leptospira spp. (16S rDNA) is a real-time PCR assay for detection of DNA of pathogenic and intermediately pathogenic Leptospira species. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. The test facilitates the rapid and sensitive detection of DNA of pathogenic and intermediately pathogenic Leptospira species from samples purified from blood, urine or kidney tissue.
Leptospira DNA can be recovered efficiently from sample material using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB00653
|
BactoReal® Kit Leptospira spp. (LipL32)
|
50 Test/Kit
|
BactoReal® Kit Leptospira spp. (LipL32) is a real-time PCR assay for detection of DNA of pathogenic Leptospira species. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. The test facilitates the rapid and sensitive detection of DNA of pathogenic Leptospira species from samples purified from blood, urine or kidney tissue. Leptospira DNA can be recovered efficiently from sample material using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB00753
|
BactoReal® Kit Leptospira spp. Multiplex (16S+LipL32)
|
50 Test/Kit
|
BactoReal® Kit Leptospira spp. Multiplex (16S+LipL32) is a multiplex real-time PCR assay for detection and differentiation of DNA of pathogenic and intermediately pathogenic Leptospira species. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. The test facilitates the rapid and sensitive detection of DNA of pathogenic and intermediately pathogenic Leptospira species from samples purified from blood, urine or kidney tissue. Leptospira DNA can be recovered efficiently from sample material using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB00853
|
BactoReal® Kit Listeria monocytogenes
|
50 Test/Kit
|
BactoReal® Kit Listeria monocytogenes is a real-time PCR assay for detection of L. monocytogenes DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Applied Biosystems),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of L. monocytogenes from samples purified from either liquor, blood or other samples (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB00953
|
BactoReal® Kit Pasteurella multocida toxA
|
50 Test/Kit
|
BactoReal® Kit Pasteurella multocida toxA is a real-time PCR assay for detection of DNA of toxigenic
P. multocida strains. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of P. multocida from samples purified from nasal fluid. Pasteurella multocida DNA can be recovered efficiently from swabs using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB01053
|
BactoReal® Kit Staphylococcus aureus
|
50 Test/Kit
|
BactoReal® Kit Staphylococcus aureus is a real-time PCR assay for detection of S. aureus DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of S. aureus from various sample materials such as swabs, biopsies and milk (e.g. with the QIAamp DNA Mini Kit extraction methods). |
|
DVEB01153
|
BactoReal® Kit Brachyspira hyodysenteriae
|
50 Test/Kit
|
BactoReal® Kit Brachyspira hyodysenteriae is a real-time PCR assay for detection of B. hyodysenteriae DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of B. hyodysenteriae from samples purified from faecal samples, or biopsies of the intestinal mucosa. Brachyspira hyodysenteriae DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from biopsies using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB01253
|
BactoReal® Kit Brachyspira pilosicoli
|
50 Test/Kit
|
BactoReal® Kit Brachyspira pilosicoli is a real-time PCR assay for detection of B. pilosicoli DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of B. pilosicoli from samples purified from faecal samples, or biopsies of the intestinal mucosa. Brachyspira pilosicoli DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from biopsies using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB01353
|
BactoReal® Kit Lawsonia intracellularis
|
50 Test/Kit
|
BactoReal® Kit Lawsonia intracellularis is a real-time PCR assay for detection of L. intracellularis DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of L. intracellularis from samples purified from faecal samples, or biopsies of the mucosal epithelium (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB01453
|
BactoReal® Kit Mycoplasma hyorhinis
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma hyorhinis is a real-time PCR assay for detection of M. hyorhinis DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. hyorhinis from samples purified from biopsies (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB01553
|
BactoReal® Kit Streptococcus agalactiae
|
50 Test/Kit
|
BactoReal® Kit Streptococcus agalactiae is a real-time PCR assay for detection of S. agalactiae DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of S. agalactiae from samples purified from milk or other sample material. |
|
DVEB01653
|
BactoReal® Kit Streptococcus uberis
|
50 Test/Kit
|
BactoReal® Kit Streptococcus uberis is a real-time PCR assay for detection of S. uberis DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of S. uberis from samples purified from milk or other sample material. |
|
DVEB01753
|
BactoReal® Kit Streptococcus dysgalactiae
|
50 Test/Kit
|
BactoReal® Kit Streptococcus dysgalactiae is a real-time PCR assay for detection of DNA of S. dysgalactiae (S. dysgalactiae subsp. equisimilis and S. dysgalactiae subsp. dysgalactiae). This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of S. dysgalactiae from samples purified from milk or other sample material. |
|
DVEB01853
|
BactoReal® Kit Brachyspira hyo/pilo
|
50 Test/Kit
|
BactoReal® Kit Brachyspira hyo/pilo is a real-time PCR assay for detection of B. hyodysenteriae and B. pilosicoli DNA. Other Brachyspira species are not detected. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive screening for DNA of B. hyodysenteriae and B. pilosicoli from samples purified from faecal samples, or biopsies of the intestinal mucosa. Brachyspira DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from biopsies using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB01953
|
BactoReal® Kit Escherichia coli
|
50 Test/Kit
|
BactoReal® Kit Escherichia coli is a real-time PCR assay for detection of E. coli DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Escherichia coli purified from sample material (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB02053
|
BactoReal® Kit Actinobacillus pleuropneumoniae
|
50 Test/Kit
|
BactoReal® Kit Actinobacillus pleuropneumoniae is a real-time PCR assay for detection of A.
pleuropneumoniae DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument
(Thermo Fisher Scientific), LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of A.
pleuropneumoniae from samples purified from tissues (e.g. lung, tonsil, etc) (e.g. with the QIAamp DNA
Mini Kit). |
|
DVEB02153
|
BactoReal® Kit Brucella spp.
|
50 Test/Kit
|
BactoReal® Kit Brucella spp. is a real-time PCR assay for detection of Brucella DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Brucella spp. from samples purified from blood, milk, lymph tissue, bone marrow and biopsies (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB02253
|
BactoReal® Kit Mycobacterium avium ssp. paratuberculosis
|
50 Test/Kit
|
BactoReal® Kit Mycobacterium avium ssp. paratuberculosis is a real-time PCR assay for detection of M. avium ssp. paratuberculosis (MAP) DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. avium ssp. paratuberculosis purified from fecal samples, milk or tissues (e.g. with the QIAamp DNA Mini Kit extraction methods). |
|
DVEB02353
|
BactoReal® Kit Salmonella enterica
|
50 Test/Kit
|
BactoReal® Kit Salmonella enterica is a real-time PCR assay for detection of Salmonella enterica DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Salmonella enterica from samples purified from swabs, feces, etc. (e.g. with the QIAamp DNA Mini Kit or the QIAamp DNA Stool Mini Kit). |
|
DVEB02453
|
BactoReal® Kit Bordetella bronchiseptica
|
50 Test/Kit
|
BactoReal® Kit Bordetella bronchiseptica is a real-time PCR assay for detection of B. bronchiseptica DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of B. bronchiseptica from samples purified from the respiratory tract (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB02553
|
BactoReal® Kit Mycoplasma bovis
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma bovis is a real-time PCR assay for detection of M. bovis DNA. This test was
developed and validated for the ABI PRISM® 7500 (Fast) instrument (Applied Biosystems), LightCycler® 480
(Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. bovis from samples purified from synovial fluid, biopsies, bronchoalveolar lavage (BAL), swabs and milk (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB02653
|
BactoReal® Kit Mycoplasma suis
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma suis is a real-time PCR assay for detection of M. suis DNA. This test was
developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480
(Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of M. suis from samples purified from blood (e.g. with the QIAamp DNA Mini Kit). Mycoplasma parvum is not detected by this test. |
|
DVEB02753
|
BactoReal® Kit Mycobacterium tuberculosis complex
|
50 Test/Kit
|
BactoReal® Kit Mycobacterium tuberculosis complex is a real-time PCR assay for detection of DNA of
Mycobacterium species belonging to the Mycobacterium tuberculosis complex, MTBC (M. tuberculosis, M.
bovis, M. caprae, M. canetti, M. africanum and M. microti). This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of members of the MTBC purified from bronchoalveolar lavage, pleural fluid, nasopharyngeal swab, nasopharyngeal aspirate, liquor, sputum, urine, whole blood, tissue and paraffine blocks (e.g. with the QIAamp DNA Mini Kit extraction methods). |
|
DVEB02853
|
BactoReal® Kit Pasteurella multocida
|
50 Test/Kit
|
BactoReal® Kit Pasteurella multocida is a real-time PCR assay for detection of P. multocida DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of P. multocida from samples purified from blood, swabs and biopsies (with the QIAamp DNA Mini Kit extraction methods, for example). |
|
DVEB02953
|
BactoReal® Kit Mannheimia haemolytica
|
50 Test/Kit
|
BactoReal® Kit Mannheimia haemolytica is a real-time PCR assay for detection of M. haemolytica DNA. This
test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of the 16S rDNA gene of M. haemolytica from DNA samples purified from tracheal swabs, washes or from lung tissue or associated lymph nodes (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB03053
|
BactoReal® Kit Chlamydophila psittaci/abortus
|
50 Test/Kit
|
BactoReal® Kit Chlamydophila psittaci/abortus is a real-time PCR assay for detection of DNA of Chlamydophila psittaci and Chlamydophila abortus. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of Chlamydophila psittaci and Chlamydophila abortus from DNA samples purified from whole blood samples, sputum, pleural fluid, biopsies or swabs (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB03153
|
BactoReal® Kit Chlamydiaceae
|
50 Test/Kit
|
BactoReal® Kit Chlamydiaceae is a real-time PCR assay for detection of DNA of Chlamydia and Chlamydophila species. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Chlamydia and Chlamydophila species from DNA samples purified from different sample material (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB03453
|
BactoReal® Kit Enterococcus spp.
|
50 Test/Kit
|
BactoReal® Kit Enterococcus spp. is a real-time PCR assay for detection of DNA of species of the genus
Enterococcus. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life
Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Enterococcus spp. from samples purified from biopsies, blood, swabs, milk, etc. (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB03653
|
BactoReal® Kit Nocardia spp.
|
50 Test/Kit
|
BactoReal® Kit Nocardia spp. is a real-time PCR assay for detection of DNA of species of the genus Nocardia. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Nocardia spp. from samples purified from biopsies, blood, swabs, milk, etc. (e.g. with the QIAamp DNA Mini Kit). This test may also detect other Actinomycetes. |
|
DVEB03753
|
BactoReal® Kit Staphylococcus spp.
|
50 Test/Kit
|
BactoReal® Kit Staphylococcus spp. is a real-time PCR assay for detection of DNA of species of the genus
Staphylococcus. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life
Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Staphylococcus spp. from samples purified from biopsies, blood, swabs, milk, etc. (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB03853
|
BactoReal® Kit Streptococcus spp.
|
50 Test/Kit
|
BactoReal® Kit Streptococcus spp. is a real-time PCR assay for detection of DNA of species of the genus
Streptococcus. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Applied
Biosystems), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Streptococcus spp. from samples purified from biopsies, blood, swabs, milk, etc. Extraction is recommended with InstaGene Matrix (Bio-Rad) or with QIAamp Viral RNA Mini Kit (Qiagen) to avoid contamination with streptococci. |
|
DVEB03953
|
BactoReal® Kit Bartonella spp.
|
50 Test/Kit
|
BactoReal® Kit Bartonella spp. is a real-time PCR assay for detection of DNA of B. clarridgeiae, B. elizabethae, B. grahamii, B. henselae, B. koehlerae, B. quintana, B. volans and B. washoensis.
Bartonella rochalimae, B. vinsonii and B. bovis are detected with very low sensitivity. Bartonella bacilliformis is not detected.
This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments.
This test allows the rapid and sensitive detection of DNA of Bartonella from samples purified blood, tissue, joint fluid, cerebrospinal fluid, pericardial effusions, lymph node aspirate and formalin-fixed paraffin-embedded tissues (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB04053
|
BactoReal® Kit E. coli Typing stx1 & stx2 (STEC)
|
50 Test/Kit
|
BactoReal® Kit E. coli Typing is a series of different real-time PCR kits for detection of virulence-associated genes of E. coli (genes stx1, stx2, eae and ehxA). Depending on which kit and which combinations of kits are used, they allow the typing of enterohemorrhagic E. coli (EHEC), enteropathogenic E. coli (EPEC) and of Shiga toxin (verotoxin) producing E. coli (STEC).
Tests were developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but are also suitable for other real-time PCR instruments.
They allow the rapid and sensitive detection of DNA of virulence-associated genes of E. coli purified from stool or other sample material (e.g. with the QIAamp DNA Stool Mini Kit). Furthermore, isolated bacterial colonies can be picket from the plate, isolated e.g. with InstaGene™ Matrix (Bio-Rad) and analysed. An internal positive control system for detection in Cy5 channel (667 nm) excludes false-negative interpretation of results due to inhibition of real-time PCR (see 8. Interpretation of PCR-data). |
|
DVEB04153
|
BactoReal® Kit E. coli Typing eae & ehxA (EHEC, EPEC)
|
50 Test/Kit
|
BactoReal® Kit E. coli Typing is a series of different real-time PCR kits for detection of virulence-associated genes of E. coli (genes stx1, stx2, eae and ehxA). Depending on which kit and which combinations of kits are used, they allow the typing of enterohemorrhagic E. coli (EHEC), enteropathogenic E. coli (EPEC) and of Shiga toxin (verotoxin) producing E. coli (STEC).
Tests were developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but are also suitable for other real-time PCR instruments. They allow the rapid and sensitive detection of DNA of virulence-associated genes of E. coli purified from stool or other sample material (e.g. with the QIAamp DNA Stool Mini Kit). Furthermore, isolated bacterial colonies can be picket from the plate, isolated e.g. with InstaGene™ Matrix (Bio-Rad) and analysed. An internal positive control system for detection in Cy5 channel (667 nm) excludes false-negative interpretation of results due to inhibition of real-time PCR (see 8. Interpretation of PCR-data) |
|
DVEB04253
|
BactoReal® Kit Clostridium difficile
|
50 Test/Kit
|
BactoReal® Kit Clostridium difficile is a real-time PCR assay for detection of DNA of Clostridium difficile toxin Aand B. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of toxigenic Clostridium difficile from samples purified from stool or other sample material (e.g. with the QIAamp DNA Stool Mini Kit).
BactoReal® Kit Clostridium difficile allows the rapid and sensitive detection of Clostridium difficile. This test is performed in a multiplex real-time PCR format to enable differentiation between Clostridium difficile toxin A from toxin B. In VIC/HEX channel the toxin A (tcdA) gene of Clostridium difficile is detected. In FAM channel the toxin B (tcdB) gene of Clostridium difficile is detected.
An internal positive control system for detection in Cy5 channel (667 nm) excludes false-negative interpretation of results due to inhibition of real-time PCR (see 8. Interpretation of PCR-data).
When using PCR-platforms not validated by ingenetix, an evaluation of the multiplex-PCR is recommended.
Please be aware that some PCR-platforms have to be calibrated with the corresponding dye before performing multiplex-PCR. |
|
DVEB04353
|
BactoReal® Kit E. coli Typing eae (EHEC or EPEC)
|
50 Test/Kit
|
BactoReal® Kit E. coli Typing is a series of different real-time PCR kits for detection of virulence-associated genes of E. coli (genes stx1, stx2, eae and ehxA). Depending on which kit and which combinations of kits are used, they allow the typing of enterohemorrhagic E. coli (EHEC), enteropathogenic E. coli (EPEC) and of Shiga toxin (verotoxin) producing E. coli (STEC).
Tests were developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but are also suitable for other real-time PCR instruments.
They allow the rapid and sensitive detection of DNA of virulence-associated genes of E. coli purified from stool or other sample material (e.g. with the QIAamp DNA Stool Mini Kit). Furthermore, isolated bacterial colonies can be picket from the plate, isolated e.g. with InstaGene™ Matrix (Bio-Rad) and analysed. An internal positive control system for detection in Cy5 channel (667 nm) excludes false-negative interpretation of results due to inhibition of real-time PCR (see 8. Interpretation of PCR-data). |
|
DVEB04453
|
BactoReal® Kit E. coli Typing ehxA (EHEC)
|
50 Test/Kit
|
BactoReal® Kit E. coli Typing is a series of different real-time PCR kits for detection of virulence-associated genes of E. coli (genes stx1, stx2, eae and ehxA). Depending on which kit and which combinations of kits are used, they allow the typing of enterohemorrhagic E. coli (EHEC), enteropathogenic E. coli (EPEC) and of Shiga toxin (verotoxin) producing E. coli (STEC).
Tests were developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but are also suitable for other real-time PCR instruments.
They allow the rapid and sensitive detection of DNA of virulence-associated genes of E. coli purified from stool or other sample material (e.g. with the QIAamp DNA Stool Mini Kit). Furthermore, isolated bacterial colonies can be picket from the plate, isolated e.g. with InstaGene™ Matrix (Bio-Rad) and analysed. An internal positive control system for detection in Cy5 channel (667 nm) excludes false-negative interpretation of results due to inhibition of real-time PCR (see 8. Interpretation of PCR-data). |
|
DVEB04553
|
BactoReal® Kit Pseudomonas aeruginosa
|
50 Test/Kit
|
BactoReal® Kit Pseudomonas aeruginosa is a real-time PCR assay for detection of P. aeruginosa DNA. This
test allows the rapid and sensitive detection of DNA of P. aeruginosa from samples purified from blood, biopsies and swabs (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB04653
|
BactoReal® Kit Taylorella equigenitalis
|
50 Test/Kit
|
BactoReal® Kit Taylorella equigenitalis is a real-time PCR assay for detection of T. equigenitalis DNA. This test allows the rapid and sensitive detection of DNA of T. equigenitalis from samples purified from swabs (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05053
|
BactoReal® Kit Borrelia burgdorferi sensu lato
|
50 Test/Kit
|
BactoReal® Kit Borrelia burgdorferi sensu lato is a real-time PCR assay for detection of DNA of Borrelia species belonging to the Borrelia burgdorferi sensu lato complex, namely Borrelia burgdorferi sensu stricto, B. garinii, B. afzelii, B. valaisiana, B. lusitaniae, B. bavariensis, B. bissettii and B. spielmanii. Borrelia spielmanii is not well detected with this assay. Borrelia causing relapsing fever are not detected.
This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of Borrelia burgdorferi sensu lato strains from samples purified from tissue, blood or cerebrospinal fluid (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05153
|
BactoReal® Kit Trueperella pyogenes
|
50 Test/Kit
|
BactoReal® Kit Trueperella pyogenes is a real-time PCR assay for detection of DNA of Trueperella pyogenes (formerly Arcanobacterium pyogenes). This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of Trueperella pyogenes from biopsies, bronchoalveolar lavage (BAL), swabs and milk (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05253
|
BactoReal® Kit Corynebacterium pseudotuberculosis
|
50 Test/Kit
|
BactoReal® Kit Corynebacterium pseudotuberculosis is a real-time PCR assay for detection of DNA of
Corynebacterium pseudotuberculosis. This test was developed and validated for the ABI PRISM® 7500 (Fast)
instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of Corynebacterium pseudotuberculosis from samples purified from biopsies (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05453
|
BactoReal® Kit American Foulbrood 1.1
|
50 Test/Kit
|
BactoReal® Kit American Foulbrood 1.1 is a real-time PCR assay for detection of Paenibacillus larvae DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument ((Thermo Fisher Scientific), LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Paenibacillus larvae from samples purified from swabs, tissues, etc. (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05553
|
BactoReal® Kit European Foulbrood
|
50 Test/Kit
|
BactoReal® Kit European Foulbrood is a real-time PCR assay for detection of Melissococcus plutonius DNA.
This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies),
LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Melissococcus plutonius from samples purified from swabs, tissues, etc. (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05753
|
BactoReal® Kit Mycoplasma gallisepticum & synoviae
|
50 Test/Kit
|
BactoReal® Kit Mycoplasma gallisepticum & synoviae is a multiplex real-time PCR assay for detection and
differentiation of DNA of Mycoplasma gallisepticum and Mycoplasma synoviae. This test was developed and
validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche) and
Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. The test facilitates the rapid and sensitive detection of DNA of M. gallisepticum and M. synoviae from samples purified from faecal samples, or swabs of tissues, exudates, diluted tissue homogenates, aspirates from the infraorbital sinuses or joint cavities, as well as from material from egg yolk or embryos. Sample pools with up to 20 samples per pool can be analyzed. Mycoplasma DNA can be recovered efficiently from faecal samples using the QIAamp DNA Stool Mini Kit, and from swabs using the QIAamp DNA Mini Kit extraction methods, for example. |
|
DVEB05853
|
BactoReal® Kit Coxiella burnetii
|
50 Test/Kit
|
BactoReal® Kit Coxiella burnetii is a real-time PCR kit for detection of Coxiella burnetii DNA. This test was developed for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and for Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Coxiella burnetii from samples purified from tissues and swabs (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB05953
|
BactoReal® Kit Riemerella anatipestifer
|
50 Test/Kit
|
BactoReal® Kit Riemerella anatipestifer is a real-time PCR kit for detection of Riemerella anatipestifer DNA. This test was developed for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and for Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of R. anatipestifer from samples purified from tissues and swabs (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB06053
|
BactoReal® Kit Streptococcus suis
|
50 Test/Kit
|
BactoReal® Kit Streptococcus suis is a real-time PCR kit for detection of S. suis DNA. This test was developed for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and for Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of S. suis from samples purified from tissues (e.g. lung, tonsil, etc) (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB06153
|
BactoReal® Kit Histophilus somni
|
50 Test/Kit
|
BactoReal® Kit Histophilus somni is a real-time PCR kit for the detection of Histophilus somni. |
|
DVEB06553
|
BactoReal® Kit Clostridium perfringens
|
50 Test/Kit
|
BactoReal® Kit Clostridium perfringens is a real-time PCR assay for detection the DNA of all five serotypes A-E of Clostridium perfringens. It is based on the amplification and detection of the 16S rRNA gene of C. perfringens. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Life Technologies), LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Clostridium perfringens from samples purified from stool, tissue, etc (e.g. with the QIAamp DNA Mini Kit). |
|
DVEB06653
|
BactoReal® Kit Ornithobacterium rhinotracheale
|
50 Test/Kit
|
BactoReal® Kit Ornithobacterium rhinotracheale is a real-time PCR assay for detection of Ornithobacterium rhinotracheale (ORT) DNA. This test was developed and validated for the ABI® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche), and for Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Ornithobacterium rhinotracheale from samples purified from tissues (e.g. with the QIAamp DNA Mini Kit). |
|
DVEF00153
|
MycoReal Kit Nosema apis & ceranae
|
50 Test/Kit
|
MycoReal Kit Nosema apis & ceranae is a real-time PCR assay for detection and differentiation of DNA of
Nosema apis and Nosema ceranae. This test was developed and validated for the ABI PRISM® 7500 (Fast)
instrument (Life Technologies), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. The test facilitates the rapid and sensitive detection of DNA of Nosema apis and Nosema ceranae from samples purified from bees (e.g. with the QIAamp DNA Mini Kit extraction methods). |
|
DVEF00253
|
MycoReal Kit Ascosphaera apis
|
50 Test/Kit
|
MycoReal Kit Ascosphaera apis is a real-time PCR kit for detection of Ascosphaera apis DNA. This test was developed for the Applied Biosystems® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and for Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Ascosphaera apis from samples purified from diseased larvae and/or honey samples (spores) (e.g. with the QIAGEN DNeasy Plant Mini Kit). Cell/spore suspensions and suspensions containing only spores have to be differentiated. Suspensions containing only spores require a more complex DNA extraction step [1]. |
|
DVEF00353
|
MycoReal® Kit Batrachochytrium dendrobatidis
|
50 Test/Kit
|
MycoReal Kit Batrachochytrium dendrobatidis is a real-time PCR kit for detection of Batrachochytrium
dendrobatidis DNA. This test was developed for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher
Scientific), LightCycler® 480 (Roche) and for Mx3005P® (Agilent), but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of Batrachochytrium dendrobatidis from samples purified from tissues and swabs (e.g. with the QIAamp DNA Mini Kit). |
|
DVEP00153
|
ParoReal Kit Echinococcus multilocularis
|
50 Test/Kit
|
ParoReal Kit Echinococcus multilocularis is a real-time PCR assay for detection of E. multilocularis DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of E. multilocularis from samples purified from biopsies (e.g. with the QIAamp DNA Mini Kit) or from feces (e.g. with the QIAamp DNA Stool Mini Kit). |
|
DVEP00353
|
ParoReal Kit Histomonas meleagridis
|
50 Test/Kit
|
ParoReal Kit Histomonas meleagridis is a real-time PCR assay for detection of H. meleagridis DNA. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific),
LightCycler® 480 (Roche) and Mx3005P® (Agilent) but is also suitable for other real-time PCR instruments. This test allows the rapid and sensitive detection of DNA of H. meleagridis from samples purified from biopsies of the cecum or liver (e.g. with the QIAamp DNA Mini Kit). |
|
DVEP00453
|
ParoReal Kit Trichinella spiralis & britovi
|
50 Test/Kit
|
ParoReal Kit Trichinella spiralis & britovi is a multiplex real-time PCR assay for detection of DNA of Trichinella spiralis and T. britovi. This test was developed and validated for the ABI PRISM® 7500 (Fast) instrument (Thermo Fisher Scientific), LightCycler® 480 (Roche) and Mx3005P® (Agilent), but is also suitable for other realtime PCR instruments. This test allows the rapid and sensitive detection and differentiation of DNA of T. spiralis and T. britovi from DNA samples purified from meat (e.g. with the QIAamp DNA Mini Kit). |